Something that I have been meaning to write up for some time now...

In nearly every environment I have worked in I have always come across some type of issue with Broadcom NICs.

In my most recent bout, it was determined that the network wasn't always (seemed to swap between having link negotation issues and invalid IP addresses) 100% initialised in WinPE before a task in the unattend.xml started executing. In our particular case we were working with Microsoft Deployment Toolkit which builds a custom WinPE image as part of deployment point synchronising.

Sample boot.bat

@echo off
echo.
echo INFO: Executing Sleep
echo.
cscript //nologo "%systemdrive%\sleep.vbs" 10
echo.
echo INFO: Renewing IP Address
ipconfig /renew
echo.
echo INFO: Executing Sleep
echo.
cscript //nologo "%systemdrive%\sleep.vbs" 10
echo.

Sample sleep.vbs

If Wscript.Arguments.Count = 0 Then
   ' Print Usage then quit
   Wscript.Echo "Usage: cscript sleep.vbs
<Number>"
   Wscript.Echo "
<Number> - Number of seconds to sleep."
   Wscript.Quit
Else
   ' Print how long we are sleeping for
   Wscript.Echo "INFO: Sleeping for " & Wscript.Arguments.Item(0) & " seconds"
   NumSeconds = Wscript.Arguments.Item(0) * 1000
   'Sleep
   Wscript.Sleep(NumSeconds)
End If

Unattend.xml Extract

<RunSynchronous>
   <
RunSynchronousCommand wcm:action="add">
      <
Description>CommandBreak WINPE Customisations</Description>
      <
Order>1</Order>
      <
Path>X:\boot.bat</Path>
  
</RunSynchronousCommand>
   <
RunSynchronousCommand wcm:action="add">
      <
Description>Lite Touch PE</Description>
      <
Order>2</Order>
      <
Path>wscript.exe X:\Deploy\Scripts\LiteTouch.wsf</Path>
   </
RunSynchronousCommand>
</
RunSynchronous>

Hardware | MDT | Network | WinPE
Navigation
Search
On this page....
Archives
<September 2008>
SunMonTueWedThuFriSat
31123456
78910111213
14151617181920
21222324252627
2829301234
567891011
Categories
Blogroll
Contact me
Send mail to the author(s) E-mail
Powered by

newtelligence dasBlog 2.0.7226.0.